The measuring chamber of the sensor is crossed by infrared radiation. When the air is introduced into this chamber, the molecules of interest absorb a part of the radiation, which reduces the intensity of the optical signal. The concentration of the gas can therefore be deduced according to the Beer-Lambert’s physical law.

NDIR ethanol Sensor

NDIR ethanol PRO Sensor

Looking for custom gas measurement solutions for your project?

Technical specifications

ETHANOL DETECTION – MODEL NUMBER CO000016
Unit of measurementBreath alcohol content (BrAC) in exhaled air: µg/L
Measurement rangeFrom 50 to 4000 µg/L 50 µg/L corresponds to the detection limit of the measuring cell
Measurement accuracy (max error)
Conditions:
– ambient temperature: 23°C (± 3°C)
– wet air inlet (>95% RH, 23°C): ethanol gas
– flow rate: ~ 0,25 L/min
± 20 µg/L @ 100 µg/L
± 40 µg/L @ 400 µg/L
SAMPLING CHARACTERISTICS
Test duration4500 ms minimum
Air inletMinimal relative pressure at measuring cell inlet port: 0.3 millibars
Maximal relative pressure at measuring cell inlet port: 10 millibars
Flow rate rangeFrom 0,1 to 1,5 L/min
Sampling period125 ms
ELECTRICAL CONDITIONS
Supply voltage3,5 VDC min
5,5 VDC max
Input current1,5 A max
Communication interfaceRS232 protocol (other on request)
Solder pad connection (recommended cable sections : ≤0.13 mm² AWG ≥ 26)


Discover our evaluation kit to help you pre-integrate and test the sensor in your systems
ENVIRONMENTAL CONDITIONS
Operating conditionsFrom 0°C to 50°C
StorageFrom -10°C to 70°C
Typical starting time (pre-heating phase) depending on the ambient temperature:@ 0°C: 160 s. / @ 10°C: 80 s. / @ 20°C: 60 s. / @ 40°C: 40 s.
PACKAGE INFORMATIONS
Dimensions and weight21 x 21 x 80 mm, 17g
External plastic casingABS PC-UL94V0
Fixing parts3 apertures (Ø 1.6 mm) compatible with self-tapping screws
(1.8 mm recommended) to fix OCIEngine

Sensor architecture

Mechanical drawings

Technical specifications

ETHANOL DETECTION – MODEL NUMBER CO00026 (Test conditions: 23°C, 50%RH, 1013 mbars)
Unit of measurementµg/L
Measurement rangeFrom 0 to 2000µg/L
Repeatability (3σ)0.5% Full Scale + 1% reading
Linearity error1% reading
Long term drift (span)1% reading
Pressure effect0.05% reading /mbar
Temperature effect0.1% reading / K
Detection limit (3σ)0.5% full scale
Cross sensitivity (3σ)Consult manufacturer
SAMPLING CHARACTERISTICS
Sampling period125 ms
Response time1s (τ=63%), at a flow rate of 1 L/min
Pressure rangeMinimal relative pressure at measuring cell inlet port: 0.3 mbar
Maximal relative pressure at measuring cell inlet port: 10 mbar
Flow rate rangeFrom 0,1 to 1,5 L/min
ENVIRONMENTAL CONDITIONS
Operating conditionsFrom 0°C to 40°C for breath analysis
From -20°C to 70°C for other applications
StorageFrom -20°C to 70°C
Typical starting time at 23°C1 minute (30 minutes at full specifications)
Humidity< 100% relative humidity (RH), not condensing
ELECTRICAL CHARACTERISTICS
Supply voltage3,7 VDC min
5,5 VDC max
Input current1,5 A max
Communication interfaceRS232 protocol: Voltage level: ±5,5V ; 3 wires mode
x3 Pico-SPOX MOLEX connector (2, 3 and 5 contacts)


Discover our evaluation kit to help you pre-integrate and test the sensor in your systems
MECHANICAL CHARACTERISTICS
Dimensions125 x 30 x 22mm
Weight~20 g
External casingPlastic
Fixing part2 tapped holes for M3 fixing. Length max=5mm

Sensor architecture